Industrial production pure water equipment is used to produce pure water for industrial production. Industrial grade pure water machines can be used for drinking water, bottled water, food industry water, semiconductor material industry production, biochemistry, electronic optics industry production water, electroplating process water, pharmaceutical industry water, analysis and diagnosis water, replacing various pure water and ultra pure water for power supply, etc.

What are the reasons for the decrease in water output of industrial pure water equipment after a long period of application, which can harm the company's productivity?

1. Membrane compaction

After the membrane is compacted, there is generally a decrease in water volume, an increase in desalination rate, high working pressure for seepage, and high temperature conditions for seepage.

2. Environmental pollution caused by organic compounds

The organic compounds in the inlet water adhere to the surface of the membrane components, causing damage to the diffusion coefficient. The ways to identify organic compound environmental pollution: analyze the intercepted substances on the security personnel filter cartridge, inspect the prepared coagulant, positive ion polyelectrolyte medium, analyze the oil and organic chemical air pollutants in the influent, and inspect cleaning agents and surfactants.

3. Low working pressure operation

Adjust the operation according to the standard working pressure specifications of the design plan.

4. Compression of membrane components

Running the machine equipment beyond the standard working pressure can cause compression of the membrane components, which require disassembly and replacement.

5. Failure to operate according to the effluent to water ratio of pure water equipment

When the pure water is adjusted above 75%, the amount of concentrated water will decrease, and the concentration rate will increase, resulting in a decrease in the amount of water passing through.

6. Hydroxides and pollutants adhere to the surface of the membrane, and bottom pressure cleaning should be carried out on time.

During operation, the pressure difference of industrial production pure water equipment increases, and membrane components need to be cleaned.

In order to ensure the normal operation and water output of pure water equipment, the actual operation of machinery and equipment must strictly follow the main parameters and operation guidelines of the effluent and water output of the machinery and equipment. The application of pure water equipment systems is very common. The pure water equipment system software of Jingde Rui adopts RO membrane separation technology and integrates Jingde Rui stable flow and pressure control technology. It is applied with external preparation and treatment facilities, and uses the principle of reverse osmosis to reasonably remove various salts and residues in the water; The system software has advantages such as stable water production, simple practical operation, low operating costs, low-carbon environmental protection, zero pollution, and convenient maintenance.