The reverse osmosis water treatment equipment adopts the currently recognized most energy-saving and advanced reverse osmosis membrane separation technology in the world, but it is not omnipotent. After using reverse osmosis for a period of time, it needs to be regularly cleaned to remove pollutants.
The specific method of cleaning is as follows.
1. To select the cleaning agent formula, prepare the solution from the water tank, and use a pump to circulate the cleaning solution to make the liquid uniform.
2. Close the inlet and outlet valves of the reverse osmosis equipment, as well as the discharge valves, and open the inlet and outlet valves of the chemical cleaning of the reverse osmosis device to form a circulating cleaning system.
3. Connect the cleaning pipeline, connect the power of the cleaning pump, set the flow rate, pressure, etc., and the cleaning operation can take 1 to 2 hours. The discharged liquid is discharged into the trench to ensure the concentration of the cleaning solution.
4. After cleaning, discharge the residual liquid from the water tank, and then put it into the appropriate water quality for flushing.
5. After the completion of each flushing stage, run the flushing and high-pressure operation according to regulations. Initially, drain the water to the trench until the water quality meets the requirements and then enter the water tank.
This is a set of cleaning methods and steps for RO membranes in reverse osmosis equipment developed by Green Health Water Treatment Company based on years of production experience. We hope this can help users avoid any worries.