The data analysis of the operation records of pure water equipment can provide some basic information for the maintenance and repair of mechanical equipment, so as to quickly identify the causes of common problems in mechanical equipment. So what is the practical significance of keeping operational records? What data information is included?

The data information that must be recorded during the operation of pure water equipment:

1. Operation record: The characteristics of the RO system software for pure water equipment should be recorded as early as possible from the beginning of the usage period. The operation report should include detailed machine and equipment descriptions, which can be solved using process diagram templates, machine and equipment diagram explanations, RORO reverse osmosis system software and post-process treatment for pure water equipment, initial preparation and solution, and RO characteristic records.

All in car instrument panels and meters should be calibrated and recorded according to the manufacturer's recommendations as much as possible.

2. RO operation data information: Operation data information can reflect the operational characteristics of RO system software for pure water equipment. All data information must be recorded during the operation period of all RO system software. This type of data information can provide raw materials for analyzing and evaluating the characteristics of RO system software for pure water equipment, including the following 11 points:

1. Flow rate (flow rate of each product water and concentrated water).

2. Pressure (for each water supply and drainage, concentrated water, and product water).

3. Temperature (water supply and drainage).

4. PH value (water supply and drainage, product water, concentrated water).

5. Conductivity (water supply and drainage, product water, each section of water supply and drainage, product water concentration).

6. Operation duration.

7. Unintentional incidents (SDI, pH and stress confusion, termination of operations, etc.)

8. All in car instrument panels and meters must be reviewed (revised) at least once every three months or six months.

9. Flow pressure, temperature, pH value, conductivity, SDI (water supply and drainage), once a day.

10. TDS analysis is conducted monthly for each section of water supply and drainage, concentrated water, and product water.

11. Clean the activated carbon filter and stainless steel pipeline with steam every week for sterilization and disinfection.