Reverse osmosis equipment is a key component of the actual operation of pure water equipment, reverse osmosis equipment, and purified water equipment system software, and it is also a very difficult part to solve. Today, the R8 editor will bring you an analysis of common faults and solutions of reverse osmosis equipment.
Common troubleshooting methods for reverse osmosis equipment
1. The reason for low pressure may be:
(1) Inadequate rate of water output;
(2) System software leakage;
(3) The water pressure in the channel of the high-pressure pump is low or there is leakage or leakage in the pump part;
(4) Fine filter element fouling;
(5) Common faults of high-pressure pumps.
2. The high pressure caused by this may be:
(1) Poor adjustment of the inlet and outlet doors of the high-pressure pump;
(2) The reverse osmosis hose from the high-pressure pump to the middle of the power plug;
(3) The concentration value of the regulated water near the above-mentioned door is tightly closed or blocked, and lower concentration water is discharged into the flow;
(4) The repair rate is too low.
3. The low utilization rate may be due to:
(1) The water flow rate is too high;
(2) Low pressure or concentration values.
4. The high utilization rate may be due to:
(1) High water supply pressure;
(2) The water flow rate is insufficient;
5. The reason for the high fluctuation of the reverse osmosis equipment may be due to two sides:
(1) The concentrated water yield is high;
(2) Environmental pollution in membrane components;
6. The reason for the termination of the high-pressure pump may be:
(1) The pump water pressure is too high (exceeding 1 and 7 MPa);
(2) The inlet water pressure of the pump is too low (less than 0.05 MPa).
7. The reasons for the reduction in reverse osmosis pure water production line equipment may be:
(1) Low water temperature;
(2) Low water pressure;
(3) The concentration of high osmotic concentration water caused by high concentration;
(4) Membrane environmental pollution.
8. The reverse osmosis water production line equipment may be improved due to:
(1) High water pressure;
(2) The temperature of water is high.
9. The reason why the production and manufacturing of reverse osmosis equipment have increased the conductivity of water and the concentration value may be due to:
(1) Environmental pollution concentration values of water pipelines or concentrated water gate valves;
(2) The repair rate is too high.
10. The high conductivity of reverse osmosis water production line equipment is due to the high concentration of water, and each one has a high gas pressure. The possible reason for this may be environmental pollution of membrane components, which limits the concentration value of water flow rate.
11. The high conductivity of reverse osmosis water production line equipment leads to increased losses on both sides of each high-pressure container. Substances with low water output may be due to environmental pollution caused by membrane components.
12. At the top of each liquid in a high-pressure container, when the water output of the material is low, the increase in the conductivity of the material water may be due to environmental pollution and traffic congestion in the safety channel of the membrane component.